Group HomeKC Controls HomeAboutProductsContact UsLinks

Mütec I/O Interface

AK4/SIL219" - RacksDIN Rail DevicesTest & Simulation

Since its foundation in 1970, Mütec has developed, produced and sold converters, transmitter, transducer, limit cards in 19”- and DIN-rail mounting (even for applications in safety areas).  Today the name Mütec Instruments GmbH stands for a wide product spectrum, a good cost-performance ratio and high quality.
        
 

DIN Rail Device

Series 3-- DIN-Rail TechnologyTechnical Data - TransmitterTech Data - Smart Transmitter in Duo Tec Failsafe

Download PDF brochure

Series 300 in 35mm DIN-Rail Technology

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back to Top

TVI 301 1-channel buffer amplifier, active
Input: 0/4-20 mA, Output: 0/4-20 mA
Auxiliary energy: 230 VAC or 24 VAC/DC
Overall width: 22.5 mm
SSV 302 2-channel signal converter
Input: 0/4-20 mA, Output: 2 x 0/4-20 mA
Auxiliary energy: 230 VAC or 24 VAC/DC
Overall width: 22.5 mm
MRI 301 Measuring transmitter for Pt100 connection or potentiometer
Output:0/4-20 mA
Auxiliary energy: 230 VAC or 24 VAC/DC
Overall width: 22.5 mm
EWB 301 RMS responsive meter for alternating current and alternating voltage
Output: 0/4-20 mA
Auxiliary energy: 230 VAC or 24 VAC/DC
Overall width: 22.5 mm
MWB 301 Averaging device Vaporization technology adjustable from 0-750 sec.
Input: 0/4-20 mA, Output: 0/4-20 mA
Auxiliary energy: 24 VAC/DC or 230 VAC
Overall width: 22.5 mm
MSI 301 1-channel-measuring transmitter supply unit
Input: 0/4-20 mA, Output 0/4-20 mA
Auxiliary energy: 24 VAC/DC or 230 VAC
Overall width: 22.5 mm
MSU 301 Feeding device (1 channel)
Output: 24 VDC
Auxiliary energy: 230 VAC, option 115 VAC
Overall width: 22.5 mm )
MSU 302 Feeding device (2 channel)
Output: 2 x 24 VDC
Auxiliary energy: 230 VAC, option 115 VAC
Overall width: 22.5 mm
AFI 301 Analogue-frequency measuring transmitter
Input: 0/4-20 mA, 0-10 VDC
Output: relay contact and open collector
Auxiliary energy: 230 VAC or 24 VAC/DC
Overall width: 22.5 mm
GUI 301 Limit switch for standard signals
Input: 0/4-20 mA, 0-10 VDC
2 limit switches, free configurable
Auxiliary energy: 230 VAC, 24 VAC Overall width: 45 mm
GPT 301

Limit switch for Pt100 or thermo couple or current or voltage inputs
1 limit switch, free configurable
Auxiliary energy: 230 VAC, 24 VAC
Overall width: 45 mm

SPI 301 Signal converter from P to I,
Execution with standard tip jack for stiff PE tube
Input: 0.2-1.0 bar or 3-15 psi,
Output: 0/4-20 mA
Auxiliary energy: 24 VAC/DC or 230 VAC
Overall width: 22.5 mm
SPI 302 2-wire signal converter from P to I
Execution with standard tip jack for stiff PE tube
Input: 0.2-1.0 bar or 3-15 psi,
Output: 0/4-20 mA
Auxiliary energy: none
Overall width: 22.5 mm
SIP 301 Signal converter from I to P
Input: 0/4-20 mA (option voltages)
Output: 0.2-1.0 bar or 3-15 psi (option split range)
Overall width: 35 mm
Option: "GW2" 2nd limit switch
Option: "A mA" Analogy output 0/4-20 mA
Option: "HE24" Auxiliary energy 24 VDC
Option: "SB" Self-sealing tip jack with additional plug for 4/6 mm tube
e.g. also for soft silicone or PVC tubes
see also picture in datasheet D 96127

Technical Data Smart-Transmitter MSK 200-T

 

 

 

 

 

Back to Top

MSK 200-T

 

 

 

 

1-channel measuring transmitter supply unit in DuoTec-Failsafe Technology self-monitoring for supply of 2-wire transmitter.
Output: 0/4-20 mA, 1-5/0-10 VDC
4 individually adjustable limit values, 2 relays contact outputs,
2 transistor outputs, 1 collective alarm relay contact
RS 232-interface at the front
RS 485-interface at the edge of the measuring device
Configuration: ON-LINE by means of MÜTEC-WINSMART software
Galvanically separated between auxiliary energy, input and output,
Auxiliary energy: 24 VDC/AC
Design: DIN-Rail mounting DIN EN 50022
Option: "iExa" Input EExia IIC
(by design 19": Option "iEx": EExib IIC (Zone 1)
Option: "AK4" Certified according to DIN 19250, class 4

Technical Data Smart-Transmitter in Duo Tec Failsafe Technology MTP 200-T

 

 

 

 

Back to Top

MTP 200-T Universal measuring transmitter in DuoTec-Failsafe Technology with self-control
Input:        Resistor and Pt100 with 2-, 3- and 4-wire switch
                all kind of thermo elements, current, voltage
Output:     0/4-20 mA, 1-5/0-10 VDC,
Galvanically separated between auxiliary energy, input and output,
4 individually adjustable limit values, 2 relay contact outputs,
2 transistor outputs, 1 collective alarm relay contact
Configuration ON-LINE by means of MÜTEC-WINSMART software.
RS 232-interface at the front,
RS 485-interface at the edge of the measuring device,
Auxiliary energy: 24VAC/DC
Design: DIN-Rail mounting, DIN EN 50022
Option: "iExa" Input EExia IIC (Zone 0)
Option: "AK4" Certified according to DIN 19250, class 4