Group HomeKC Controls HomeAboutProductsContact UsLinks

Mütec I/O Interface

AK4/SIL219" - RacksDIN Rail DevicesTest & Simulation

Since its foundation in 1970, Mütec has developed, produced and sold converters, transmitter, transducer, limit cards in 19”- and DIN-rail mounting (even for applications in safety areas).  Today the name Mütec Instruments GmbH stands for a wide product spectrum, a good cost-performance ratio and high quality.
        
 

19" - Racks

Measuring TransmitterMeasuring Transmitter Supply UnitsBuffer AmplifierCurrent & Voltage SIgnal MultiplierSignal Converter Pneumatic:Current/Voltage

Signal Converter Current/Voltage:PneumaticAccessories19" Rack

 

Measuring Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back to Top

MRT 200 Pin-compatible device for the rack series RC10/RC12 and TC10/TC12
Input: Resistance and Pt100 in 2-, 3- and 4-wire switch as well as thermo element,
Output: 0/4-20 mA, 1-5/0-10 VDC,
2 individually adjustable limit values, 2 relay contact outputs
Configuration ON-LINE by means of MÜTEC-WINSMART software.
RS 232-interface at the front,
Galvanically separated between auxiliary energy, input and output,
Auxiliary energy: 24 VAC/DC,
Design: 19", 4TE, 3H
Option: "ib" Input Zone 1, EExib IIC
WINSMART
MRT
Configuration software for MRT 200...
MRT under WINDOWS 95, 98 + NT
Configuration and calibration is done by the software.
MRI 203 Measuring transmitter for Pt100 in 2-, 3-, or 4-wire switch.
With testing socket, LED for break of the sensing device respectively conduction break and auxiliary energy, galvanically separated between input, output and auxiliary energy, variable adjustment of the measuring range, change-over break message, switch-over output signal 0/4-20 mA
Auxiliary energy: 24 VAC/VDC
Design: 19", 4TE, 3HE
MRI 203POT Measuring transmitter for potentiometer connection and resistance input
Basic data like MRI 203, however , the measuring range is adjusted according to DIN 43822 or demand of the client.
Standard measuring range: 0-1kW or 0-10kW
MRI 203DT Measuring transmitter for difference in temperature measuring with 2 inputs of PT100 as 3-wire with conduction compensation smallest measuring range: 5° C, calibration according to client's demand, further basic data like MRI 203
  Options:
Option: "TA" Additional transistor output for break and short circuit
Option: "SM" Special measuring range outside the measuring distance
Option: "SA" Voltage output
Option: "ib" Input  Zone 1, EEx II C
Option: "ia" Input  Zone 0, EEx II C
Option: "ibo" Input  Zone 1, EEx II C
Output Zone 1, EEx II C
Option: "iao" Input Zone 0, EEx II C
Output Zone 1, EEx II C
Measuring Transmitter Supply Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back to Top

MSU 101 1-channel measuring transmitter supply unit galvanically separated between auxiliary energy and output,
Output: 24 V/100 mA,
Auxiliary energy: 24, 115 or 230 VAC
Design: 19", 7TE, 3HE
MSU 102
 
2-channel measuring transmitter supply unit
Channels galvanically separated, all other like MSU 101
MSU 103 3-channel measuring transmitter supply unit
Channels galvanically separated, all other like MSU 101
MSU 104 4-channel measuring transmitter supply unit
Channels galvanically separated, all other like MSU 101
MSU 201 1-channel universal measuring transmitter supply unit and buffer amplifier
with following functions:
Transmitter feeding, buffer amplifier, break and short circuit message with LED at the front. At conduction break and/or short circuit the output signal is alternatively controlled open or closed, the valueis free adjustable with a 20 gear trimmer from 0-23 mA, galvanically separated between input, output and auxiliary energy
Output: 0/4-20 mA or 1-5/0-10 VDC
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
  Options:
Option: "ib" Intrinsically safe input for zone 1, EExib
Option: "io" Intrinsically safe output for zone 1, EExib
Option: "ieo" Intrinsically safe input and output for zone 1, EExib
Option: "Rad" Evolution Output
Option: "TA" Transistor output for break and short circuit
MSI 241 1-channel measuring transmitter supply unit
With 4 galvanically separated outputs like SSV 200 galvanically separated between input, output and auxiliary energy,
Output: 0/4-20 mA or 1-5/0-10 VDC
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
MSI 242 Like described under MSI 241, however, with 2 channel measuring transmitter supplies for each input 2 galvanically separated outputs
MSI 241i 1-channel measuring transmitter supply unit in Ex-version.
With 4 galvanically separated outputs as well as galvanically separated between input, output and auxiliary energy
Intrinsically safe input for zone 1, EExib
Output: 0/4-20 mA or 1-5/0-10 VDC
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
(not pin compatible to MSI 241)
Buffer Amplifier

 

 

 

 

 

 

Back to Top

TVI 201 Active 1 channel buffer amplifier
Accuracy class 0.1; break and short circuit message with LED at the front. At conductor break and/or short circuit message, the output signal is alternatively controlled open or closed, the valueis free adjustable with a 20 gear trimmer from 0-23 mA, galvanically separated between input, output and auxiliary energy.
Output: 0/4-20 mA oder 1-5/0-10 VDC,
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
  Option:
Option: "ib" Intrinsically safe input for zone 1, EExib
Option: "io" Intrinsically safe output for zone 1, EExib
Option: "ieo" Intrinsically safe input and output for zone 1, EExib
Current and Voltage Signal Multiplier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back to Top

SSV 200 Current signal multiplier for standard signal
1 input as mA or voltage, 4 outputs as mA 0/4-20 mA.
input to output and auxiliary energy galvanically separated,
Outputs also galvanically separated with testing sockets for each output channel,
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
SSV 201 Current signal multiplier for standard signals
1 input as mA or voltage, 4 outputs 0/4-20 mA.
reversible to 2 inputs as mA or voltage and each input 2 outputs
as 0/4-20 mA
further data like SSV 200
SSV 202 Current signal multiplier for standard signals
1 input as mA or voltage, 4 outputs as voltage 1-5/0-10 VDC galvanically separated between input, output and to the auxiliary energy
Outputs also galvanically separated
with testing socket for each output channel
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
SSV 203 Current signal multiplier for standard signals
1 input as mA or voltage, 4 outputs as voltage 1-5/0-10 VDC
switch able to 2 inputs as mA or voltage and each input
2 outputs as embossed voltage 1-5/0-10 VDC
further data like SSV 202
Option: "Gem" Mixed unit signals mA and V
Option: "Ob" Upper mA signal limit outside standard
Option: "Ub" Lower mA signal limit, e.g. 3.7 mA
Option: "Inv" Inverting e.g. input 4-20 mA, output 20-4 mA
Option: "Lup" Split/Range function, e.g. input 4-20 mA and output 12-20 mA
Signal Converter Pneumatic into Current or Voltage

 

 

 

 

 

 

 

 

Back to Top

SPI 200 1-channel P→I signal converter
Unit signals, e.g. 0.2-1.0 bar or 3-15 psi
Output: 0/4-20 mA
Auxiliary energy: 24 VAC/VDC
Design: 19", 4TE, 3HE
SPI 201 2-channel P → I signal converter, further data like SPI 201
  Options:
Option: "Pb" for pneumatic testing sockets each channel
SPI 221 1-channel P → I signal converter in 2-wire technology
Design: 19", 4TE, 3HE
SPI 222 2-channel P → I signal converter in 2-wire technology
Design: 19", 4TE, 3HE
  Options:
Option: "Pb" for pneumatic testing sockets each channel
SPI 103 P → I signal converter, in stainless steel housing IP65 in 2-wire technology to install into the production plant and in rough surroundings threaded screw G ½" or ¼" NPT
Signal Converter Current/Voltage into Pneumatic

 

 

 

 

 

 

Back to Top

SIP 100 1-channel I → P - signal converter,
Input e.g. 0 or 4-20 mA
Output: 0.2-1.0 bar or 3-15 psi
Additional air: 1.4 bar
Design: 19", 7TE, 3HE
SIP 101 2-channel I → P signal converter,
further data like SIP 100
SIP 201 1-channel I → P signal converter
Inputs e.g. 0 or 4-20 mA
Output: 0.2-1.0 bar or 3-15 psi
Additional air: 1.4 bar
Design: 19", 4TE, 3HE
SIP 202 2-channel I → P signal converter,
further data like SIP 201
Special requirements
  Further devices by enquiry
Accessories like housings/connectors sub-racks, blind plates etc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back to Top

FGM Field housing type FGM, class: IP65, material: Macrolon
FGP Field housing type FGP, class: IP65, material: Polyester
SVC 100 Snap buckle for front plates, chromated, per pair
SVS 100 Snap buckle for front plates, black, per pair
FÜR 100 DIN-rail, per pair
FED 132 Multiple connector with soldered connection and mounting accessory form F 32-pole
FED 132i 32-pole, as above however coded for EExi application
FED 133 Special multiple connector for MTP 200 and MSK 200
With soldered connection and mounting accessory form F 33-pole
FED 133i 33-pole, as above, however, coded for EExi application
FED 148 Multiple connector, like FED 132, however 48-poleg
FED 148i 48-pole like before, however coded for EExi application
MES 132 32-pole multiple plug
PIP 202 Electro-pneumatic connecting plate
for SIP 100, SIP 101, SIP 201, SIP 202
PPI 201 Electro-pneumatic connecting plate
for 1-channel signal converter
PPI 202 Electro-pneumatic-connecting plate
for 2-channel SPI 202 signal converter
TR 19 T Sub-rack, 3 HE, for switchboard mounting
or rack mounting pre-mounted
TR 19 W Sub-rack, 3 HE, for switchboard mounting
or rack mounting pre-mounted
WB 1 Thermo conducting sheet metal
with 1 HE nameplate and PVC-lettering rail, mounted
RW Fold out back tub for plugs or clamps, mounted
Extra price for plug countersinking or further processing
GS 84 84 TE thread rail for front plate mounting
FP 4/3 Front plate as partial plug-in without lettering 4 TE, 3 HE
FP 6/3 ditto, however 6 TE, 3 HE
FP 7/3 ditto, however 7 TE, 3 HE
FP 14/3 ditto, however 14 TE, 3 HE
FP 21/3 ditto, however 21 TE, 3 HE
FP 40/3 ditto, however 40 TE, 3 HE
FP 42/3 ditto, however 42 TE, 3 HE
FP 60/3 ditto, however 60 TE, 3 HE
FP 84/3 ditto, however 84 TE, 3 HE
BPL 2 Blind plate blank on 19" full covering, 3 mm thick, 2 HE
BPL 3 ditto, however 3 HE
BPL 4 ditto, however 4 HE
BPL 6 dito, however 6 HE
BPL 9 dito, however 9 HE
MS 19 Mounting set 19" cage nuts + screws + disk as set (100 pcs.)
BT 1 Nameplate 1 HE with plastic disk and -stripes
BL Nameplate made of PVC- with paper stripes
MW 19 Mütec certificate
Detailed certificate for 19" -units
TAG TAG-number label
Additional label for TAG-number at the front panel
19" Rack

 

Back to Top

BGT TVI 19" Rack on 5 m cable ends wired for 21 pcs TVI 201 (also with EExi wiring)
BGT MSK 19" Rack on 5 m cable ends wired for 21 pcs MSK 200 (also with EExi wiring)
BGT MTP 19" Rack on 5 m cable ends wired for 21 pcs. MPT 200 (also with EExi wiring)
BGT MRT 19" Rack on 5 m cable ends wired for 21 pcs TC/RC 10/12 (also with EExi wiring)