19" -
Racks
|
Measuring Transmitter
|
|
MRT 200 |
Pin-compatible device for the rack series RC10/RC12 and
TC10/TC12
Input: Resistance and Pt100 in 2-, 3- and 4-wire switch
as well as
thermo element,
Output: 0/4-20 mA, 1-5/0-10 VDC,
2 individually adjustable limit values, 2 relay contact
outputs
Configuration ON-LINE by means of MÜTEC-WINSMART
software.
RS 232-interface at the front,
Galvanically separated between auxiliary energy, input
and output,
Auxiliary energy: 24 VAC/DC,
Design: 19", 4TE, 3H |
Option:
"ib" |
Input Zone
1, EExib IIC |
WINSMART
MRT |
Configuration software for MRT 200...
MRT under WINDOWS 95, 98 + NT
Configuration and calibration is done by the
software. |
MRI 203 |
Measuring
transmitter for Pt100 in 2-, 3-, or 4-wire switch.
With testing socket, LED for break of the sensing device
respectively conduction break and auxiliary energy,
galvanically separated between input, output and
auxiliary energy,
variable adjustment of the measuring range, change-over
break message, switch-over output signal 0/4-20 mA
Auxiliary energy: 24 VAC/VDC
Design: 19", 4TE, 3HE |
MRI 203POT |
Measuring
transmitter for potentiometer connection and resistance
input
Basic data like MRI 203, however , the measuring range
is adjusted according
to DIN 43822 or demand of the client.
Standard measuring range: 0-1kW or 0-10kW |
MRI 203DT |
Measuring
transmitter for difference in temperature measuring with 2
inputs of
PT100 as 3-wire with conduction compensation
smallest measuring range: 5° C, calibration according to
client's demand,
further basic data like MRI 203 |
|
Options: |
Option:
"TA" |
Additional
transistor output for break and short circuit |
Option:
"SM" |
Special
measuring range outside the measuring distance |
Option:
"SA" |
Voltage
output |
Option:
"ib" |
Input Zone
1, EEx II C |
Option:
"ia" |
Input Zone
0, EEx II C |
Option:
"ibo" |
Input Zone
1, EEx II C
Output Zone 1, EEx II C |
Option:
"iao" |
Input Zone
0, EEx II C
Output Zone 1, EEx II C |
|
|
Measuring Transmitter
Supply Units
|
|
MSU 101 |
1-channel
measuring transmitter supply unit
galvanically separated between auxiliary energy and
output,
Output: 24 V/100 mA,
Auxiliary energy: 24, 115 or 230 VAC
Design: 19", 7TE, 3HE |
MSU 102
|
2-channel
measuring transmitter supply unit
Channels galvanically separated, all other like MSU 101 |
MSU 103 |
3-channel
measuring transmitter supply unit
Channels galvanically separated, all other like MSU 101 |
MSU 104 |
4-channel
measuring transmitter supply unit
Channels galvanically separated, all other like MSU 101 |
MSU 201 |
1-channel
universal measuring transmitter supply unit and buffer
amplifier
with following functions:
Transmitter feeding, buffer amplifier, break and short
circuit message
with LED at the front. At conduction break and/or short
circuit
the output signal is alternatively controlled open or
closed, the valueis free adjustable with a 20 gear trimmer from 0-23 mA,
galvanically separated between input, output and
auxiliary energy
Output: 0/4-20 mA or 1-5/0-10 VDC
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE |
|
Options: |
Option:
"ib" |
Intrinsically safe input for zone 1, EExib |
Option:
"io" |
Intrinsically safe output for zone 1, EExib |
Option:
"ieo" |
Intrinsically safe input and output for zone 1, EExib |
Option:
"Rad" |
Evolution
Output |
Option:
"TA" |
Transistor
output for break and short circuit |
MSI 241 |
1-channel measuring transmitter supply unit
With 4 galvanically separated outputs like SSV 200
galvanically separated between input, output and
auxiliary energy,
Output: 0/4-20 mA or 1-5/0-10 VDC
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE |
MSI 242 |
Like
described under MSI 241,
however, with 2 channel measuring transmitter supplies
for each input 2 galvanically separated outputs |
MSI 241i |
1-channel
measuring transmitter supply unit in Ex-version.
With 4 galvanically separated outputs as well as
galvanically separated between input, output and
auxiliary energy
Intrinsically safe input for zone 1, EExib
Output: 0/4-20 mA or 1-5/0-10 VDC
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE
(not pin compatible to MSI 241) |
|
|
Buffer Amplifier
|
|
TVI 201
|
Active 1
channel buffer amplifier
Accuracy class 0.1; break and short circuit message with
LED at the
front. At conductor break and/or short circuit message,
the output
signal is alternatively controlled open or closed, the
valueis free adjustable with a 20 gear trimmer from 0-23 mA,
galvanically separated between input, output and
auxiliary energy.
Output: 0/4-20 mA oder 1-5/0-10 VDC,
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE |
|
Option: |
Option:
"ib" |
Intrinsically safe input for zone 1, EExib |
Option:
"io" |
Intrinsically safe output for zone 1, EExib |
Option:
"ieo" |
Intrinsically safe input and output for zone 1, EExib |
|
|
Current and Voltage
Signal Multiplier
|
|
SSV 200
|
Current
signal multiplier for standard signal
1 input as mA or voltage, 4 outputs as mA 0/4-20 mA.
input to output and auxiliary energy galvanically
separated,
Outputs also galvanically separated
with testing sockets for each output channel,
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE |
SSV 201
|
Current
signal multiplier for standard signals
1 input as mA or voltage, 4 outputs 0/4-20 mA.
reversible to 2 inputs as mA or voltage and each input 2
outputs
as 0/4-20 mA
further data like SSV 200 |
SSV 202 |
Current
signal multiplier for standard signals
1 input as mA or voltage, 4 outputs as voltage 1-5/0-10
VDC
galvanically separated between input, output and to the
auxiliary energy
Outputs also galvanically separated
with testing socket for each output channel
Auxiliary energy: 24 VDC/VAC,
Design: 19", 4TE, 3HE |
SSV 203
|
Current
signal multiplier for standard signals
1 input as mA or voltage, 4 outputs as voltage 1-5/0-10
VDC
switch able to 2 inputs as mA or voltage and each
input
2 outputs as embossed voltage 1-5/0-10 VDC
further data like SSV 202 |
Option:
"Gem" |
Mixed unit
signals mA and V |
Option:
"Ob" |
Upper mA
signal limit outside standard |
Option:
"Ub" |
Lower mA
signal limit, e.g. 3.7 mA |
Option:
"Inv" |
Inverting
e.g. input 4-20 mA, output 20-4 mA |
Option:
"Lup" |
Split/Range
function, e.g. input 4-20 mA and output 12-20 mA
|
|
|
Signal
Converter Pneumatic into Current or Voltage
|
SPI 200
|
1-channel P→I
signal converter
Unit signals, e.g. 0.2-1.0 bar or 3-15 psi
Output: 0/4-20 mA
Auxiliary energy: 24 VAC/VDC
Design: 19", 4TE, 3HE |
SPI 201
|
2-channel P → I
signal converter, further data like SPI 201 |
|
Options: |
Option: "Pb"
|
for
pneumatic testing sockets each channel |
SPI 221
|
1-channel P → I
signal converter in 2-wire technology
Design: 19", 4TE, 3HE |
SPI 222 |
2-channel P → I
signal converter in 2-wire technology
Design: 19", 4TE, 3HE |
|
Options: |
Option: "Pb"
|
for
pneumatic testing sockets each channel |
SPI 103
|
P → I signal
converter, in stainless steel housing IP65 in 2-wire technology
to install into the production plant and in rough surroundings
threaded screw G ½" or ¼" NPT |
|
Signal
Converter Current/Voltage into Pneumatic
|
SIP 100
|
1-channel I → P -
signal converter,
Input e.g. 0 or 4-20 mA
Output: 0.2-1.0 bar or 3-15 psi
Additional air: 1.4 bar
Design: 19", 7TE, 3HE |
SIP 101
|
2-channel I → P
signal converter,
further data like SIP 100 |
SIP 201 |
1-channel I → P signal converter
Inputs e.g. 0 or 4-20 mA
Output: 0.2-1.0 bar or 3-15 psi
Additional air: 1.4 bar
Design: 19", 4TE, 3HE |
SIP 202 |
2-channel I → P
signal converter,
further data like SIP 201 |
Special
requirements |
|
Further devices by
enquiry |
|
Accessories like housings/connectors sub-racks, blind plates etc
|
|
FGM |
Field
housing type FGM, class: IP65, material: Macrolon |
FGP |
Field
housing type FGP, class: IP65, material: Polyester |
SVC 100 |
Snap buckle
for front plates, chromated, per pair |
SVS 100 |
Snap buckle
for front plates, black, per pair |
FÜR 100 |
DIN-rail,
per pair |
FED 132 |
Multiple
connector with soldered connection and mounting
accessory form F 32-pole |
FED 132i |
32-pole, as
above however coded for EExi application |
FED 133 |
Special
multiple connector for MTP 200 and MSK 200
With soldered connection and mounting accessory form F
33-pole |
FED 133i |
33-pole, as
above, however, coded for EExi application |
FED 148 |
Multiple
connector, like FED 132, however 48-poleg |
FED 148i |
48-pole
like before, however coded for EExi application |
MES 132 |
32-pole
multiple plug |
PIP 202 |
Electro-pneumatic connecting plate
for SIP 100, SIP 101, SIP 201, SIP 202 |
PPI 201 |
Electro-pneumatic connecting plate
for 1-channel signal converter |
PPI 202 |
Electro-pneumatic-connecting plate
for 2-channel SPI 202 signal converter |
TR 19 T |
Sub-rack, 3
HE, for switchboard mounting
or rack mounting pre-mounted |
TR 19 W |
Sub-rack, 3
HE, for switchboard mounting
or rack mounting pre-mounted |
WB 1 |
Thermo
conducting sheet metal
with 1 HE nameplate and PVC-lettering rail, mounted
|
RW |
Fold out
back tub for plugs or clamps, mounted
Extra price for plug countersinking or further
processing |
GS 84 |
84 TE
thread rail for front plate mounting |
FP 4/3 |
Front plate
as partial plug-in without lettering 4 TE, 3 HE
|
FP 6/3 |
ditto,
however 6 TE, 3 HE |
FP 7/3 |
ditto,
however 7 TE, 3 HE |
FP 14/3 |
ditto,
however 14 TE, 3 HE |
FP 21/3 |
ditto,
however 21 TE, 3 HE |
FP 40/3 |
ditto,
however 40 TE, 3 HE |
FP 42/3 |
ditto,
however 42 TE, 3 HE |
FP 60/3 |
ditto,
however 60 TE, 3 HE |
FP 84/3 |
ditto,
however 84 TE, 3 HE |
BPL 2 |
Blind plate
blank on 19" full covering, 3 mm thick, 2 HE |
BPL 3 |
ditto,
however 3 HE |
BPL 4 |
ditto,
however 4 HE |
BPL 6 |
dito,
however 6 HE |
BPL 9 |
dito,
however 9 HE |
MS 19 |
Mounting
set 19" cage nuts + screws + disk as set (100 pcs.) |
BT 1 |
Nameplate 1
HE with plastic disk and -stripes |
BL |
Nameplate
made of PVC- with paper stripes |
MW 19 |
Mütec
certificate
Detailed certificate for 19" -units |
TAG |
TAG-number
label
Additional label for TAG-number at the front panel
|
|
|
19" Rack
|
|
BGT TVI
|
19" Rack on
5 m cable ends wired for 21 pcs TVI 201 (also with EExi
wiring) |
BGT MSK
|
19" Rack on
5 m cable ends wired for 21 pcs MSK 200 (also with EExi
wiring) |
BGT MTP
|
19" Rack on
5 m cable ends wired for 21 pcs. MPT 200 (also with EExi
wiring) |
BGT MRT
|
19" Rack on
5 m cable ends wired for 21 pcs TC/RC 10/12 (also with
EExi wiring) |
|
|